Filter Results By:

Products

Applications

Manufacturers

Ground Resistance

Evaluation of the conductance of earth grounding.

See Also: Ground Resistance Clamps, Ground Resistance Testers, Surface Resistivity


Showing results: 121 - 135 of 136 items found.

  • NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    785186-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module

    783864-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9217, 4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    779592-01 - NI

    4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9217 is a resistance temperature detector (RTD) input module. You can configure the NI‑9217 for two sample rate modes: high sample rate or high resolution. The NI‑9217 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9217 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module

    783863-02 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module

    785189-01 - NI

    8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.

  • POWER PROBE 4

    PP401 - Matco Tools

    *Electronic circuit and component tester that supplies battery ground and power along with 8 diagnostic testing modes to provide automotive technicians with detailed information on the circuits and signals being tested*Diagnostic Modes include: AC/DC Voltmeter, Ohmmeter, Frequency, Pulse width (Positive and Negative) Fuel Injector Tester, PCM/ECM Driver Tester and PPECT3000 Signal tracer*Tests for AC/DC voltage in 100ms and 50s resolutions, AC volts RMS and volts peak-to-peak, measure resistance, frequency and pulse width (negative and positive)

  • AC Ground Bond Tester

    446 - SCI

    Our 446 model is a 4-in-1 tester with AC Hipot, DC Hipot, Insulation Resistance, and Ground Bond capabilities. This tester features a simple design and easy-to-use interface, reducing setup time and increasing production-line throughput for your application. The 446 is equipped with multiple memories and an optional USB port for remote BUS communication so you can quickly perform tests on a variety of DUTs from the front panel or with a PC. Add to user safety by equipping your tester with Personal Protective Equipment (PPE) via the built-in safety interlock.

  • Digital Ior Leakage Current Clamp Tester

    MCL-400IR+ - MULTI MEASURING INSTRUMENTS Co., Ltd.

    ・About Ior Leakage CurrentRecently, the leakage current clamp meter is widely used for insulation control of low voltage circuit as the supplementary method of the insulation resistance measurement. The control of leakage current has the advantages to enable the prediction of insulation condition in the electrical power line without having to shut off the power. The leakage current (Io) includes the capacitive leakage current (Ioc)originated in the capacitance and the resistive leakage current (Ior) originated in the insulation resistance each related to the ground. It is considered that the measurement of resistive leakage current (Ior) is the very useful and effective method for the insulation control of low voltage circuit. However, it was difficult to measure the resistive leakage current (Ior)with traditional leakage current clamp meter. MCL-400IR new digital clamp tester enabled the measurements of the resistive leakage current (Ior)without voltage input(phase detection).

  • The Mag Lead

    136 - Electronic Specialties Inc.

    *Mag Lead features a magnetic disconnect near the test probe end. *Just disconnect the test probe and you can “stick” to any metallic ground or test point. *Quit fumbling with alligator clips that fall off - Mag Lead’s powerfull magnet will hold tight! *This is a time saving tool - if you don’t have to walk to your tool box to retrieve your alligator clips, even on just half the occasions, then you’ve saved time. *Very helpful for automotive reference points and troubleshooting. *Can eliminate the need to hold probes while checking or monitoring a signal. *Two high power, low resistance magnets hold the probe to the lead. *Fits almost all Digital Multimeters and can be used with hand-held scopes too. *Get the Mag Lead, it stays put and won’t fall off, like alligator clips do!

  • Electrical Safety Testers- Hipots

    Salicon Nano Technology

    Safety testers (also named hi-pot tester/hipot tester/hipot test) are designed to ensure safe operation of DUTs under various operating conditions and environment.GW Instek’s GPT-9900/GPT-9800/9600 series safety testers(hipot test) provide safe and quick measurement tools for AC/DC withstanding voltage tests, insulation resistance tests, and AC ground bond tests. Those tests are required by many international safety regulations such as CE, UL, VDE, and etc. We also have leakage current tester, GLC-9000, which supports all the major leakage current test standards for medical and general electronic equipment.

  • AC Ground Bond Testers

    440 Series - SCI

    The 440 Series provides advanced 4-in-1 test capability in a convenient one-box solution. This new series performs AC Hipot (448 - 500 VA), DC Hipot, Insulation Resistance and 40A AC Ground Bond tests while taking up minimal production line space. The 440 Series is simple and easy-to-use; reducing setup time and increasing production line throughput for your application. With multiple memories and an optional USB port for remote BUS communication so you can quickly perform tests on a variety of DUTs from the front panel or with a PC. Learn about our 5 Year Warranty.

  • Ground Grid Tester

    GGT Series - IBEKO Power AB

    The GGT500 ground grid integrity tester is designed for inspection of the substation ground grid. It can also be used as a portable micro-ohmmeter with Both Sides Grounded and Remote Control functionalities. It is intended to inspection the conditions of a grounding system beneath substations, testing of medium- and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links.In the United States when inspecting the quality of the grounding systems beneath a substation, the proper procedure is to inject 300 A DC during a time period of 60 s. This is what the GGT500 will do, and in that time period, the current path and voltage drop are checked. Also acting as a micro-ohmmeter, the GGT500 can test low resistance values by producing high test currents of up to 500 A.The instrument is placed in an unbreakable, plastic case with IP67 protective rating (with closed lid). Although very portable and lightweight, micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents, as well as the use of thinner/longer test cables. GGT500 ground grid integrity tester generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. This significantly decreases magnetic transients and ensures great accuracy.When used for testing in Both Sides Grounded conditions, a special current clamp powered from the ground grid integrity tester is used for measuring a current through groundings. If even a higher safety level is required, the remote control feature enables the operator to perform measurements from a distant location, away from the instrument and test object.

  • Surface Resistance System Kit

    PRS-801RM - Prostat Corporation

    - Perform Point-to-Point and Resistance to Ground Measurements from 0.01 Ω to 200 Teraohms- Accuracy of ±2% from 1.00 Ω to 9.99x1010Ω- Measures in accordance with ESD TR53, ANSI/ESD S4.1, ANSI/ESD S7.1, ANSI/ESD STM97.1 and others- Constant Test voltages 10V and 100V meeting ANSI/ESD S20.20- Operates using a Rechargeable Li-ion Battery Pack- Takes Approximately 8,000 Measurements on a Single Charge (480 hours typical)- Stores up to 999 Test Values Into Memory- Compatible with Prostat Connect 2.0 for Downloading into Excel®- Charging and Download via Standard Micro USB Cable- Includes 5lb Conductive Probes and Carrying Case- Certificate of Calibration Traceable to NIST included- 2-year Limited Warranty on Main Instrument

  • Advanced Cable Tester v2

    TP800110 - Total Phase Inc.

    The Total Phase Advanced Cable Tester v2 is the quickest and most convenient way to comprehensively test USB, Lightning, and video cables. It provides:*Short testing - Dynamic visualization of test results*Open testing - Dynamic visualization of test results*Continuity testing - Dynamic visualization of test results*DC resistance measurement for most wires, with milliohm precision on ground and power wires, ohm resolution on most other wires, continuity check only on high-speed data lines*Signal integrity testing of data lines to 12.8 Gbps per channel*E-Marker verification*Lightning plug bring up/function (Apple Lightning Cables)**Over-voltage protection (Apple Lightning Cables)**Voltage recovery testing (Apple Lightning Cables)**Quiescent current consumption (Apple Lightning Cables)*

  • Continuity of Insulation Tester (High Voltage Method)

    ZGQ-16B - Shanghai Dean Electrical Co., Ltd

    Executive standard: GB/T4074.5-2008/IEC60851-5;Inspection standard: JB/T4279.13-2008Meet GB/T6109-2008 standard requirementsUsed to test the Insulation continuity (namely the pinhole number of enameled wire sample per unit length) of enameled round wires with nominal conductor diameter ranging from0.05mmto1.60mm;8 level test voltages can be selected by pressing button: 350V, 500V, 750V, 1000V, 1500V, 2000V, 2500V and 3000V;Test length ranging 0~99m;Application of SCM control.Automatically complete test process, display wire testing length and pinhole number;Brushless driving motor, guide pulley and take up pulley are equipotent.The electrode insulation to ground, using high resistance material of non-hygroscopic, no leakage, no tracking, easy to clean, Insulation thickness can ensure long-term 3000V voltage effect.Circuit board is subject to anti-static and moistureproof and long-time aging treatment, has more stable quality and higher durability;

Get Help